One of the reasons for not achieving satisfactory indices of Power Quality (PQ) is due to the discontinuity of power supply in Distribution Systems (DS), usually caused by the occurrence of short-circuits. In this context, to characterize these occurrences, a database was compiled by simulations in the IEEE 34-bus DS using the ATP (Alternative Transients Program) software. In these simulations, the type, location and fault impedance were used as parameters. The voltages and currents of all three phases of the power quality meters optimally allocated in the DS were considered. Based on these measurements, the J48 decision tree algorithm was used to identify in which area of the 34-bus DS the single-phase faults occurred. In order to use the J48 decision tree, the WEKA (Waikato Environment for Knowledge Analysis) software was used. Promising results demonstrated the effectiveness of the proposed algorithm to locate the single-phase short-circuit situations considered.
机译:无法获得令人满意的电能质量(PQ)指标的原因之一是由于配电系统(DS)中的电源中断,通常是由短路引起的。在这种情况下,为了表征这些事件,使用ATP(备用瞬态程序)软件通过IEEE 34总线DS中的仿真来编译数据库。在这些仿真中,类型,位置和故障阻抗被用作参数。考虑了在DS中最佳分配的电能质量表的所有三相的电压和电流。基于这些测量,使用J48决策树算法来识别单相故障发生在34总线DS的哪个区域。为了使用J48决策树,使用了WEKA(Waikato知识分析环境)软件。有希望的结果证明了该算法在定位所考虑的单相短路情况下的有效性。