This paper proposes possible solutions to mitigate voltage sag problem in Kaliwungu Industrial Center, Central Java, Indonesia. In the last three years, there were 17 voltage sag occurrences which violate the ITIC curve. In Central Java area, Kaliwungu in particular, suffers from unbalanced deep voltage sags due to application of Y-Y connected transformers from the upstream 500 kV backbone to the 380 V low voltage distribution. Thus, voltage sag due to unbalanced fault elsewhere in the Central Jawa grid will directly pass to the consumer appliances in Kaliwungu Industrial Center. Several relatively low-cost solutions have been proposed to mitigate this situation. The proposed solutions are to modify the transformer winding connections and the grounding system in the substation that feeds directly the area. Simulated results show the effectiveness of the proposed solution.
机译:本文提出了可能的解决方案,以缓解印度尼西亚中爪哇省Kaliwungu工业中心的电压暂降问题。在过去三年中,发生了17次违反ITIC曲线的电压骤降。特别是在中爪哇省中部地区,由于从上游500 kV主干到380 V低压配电应用了Y-Y连接变压器,因此卡利旺古遭受了不平衡的深电压骤降。因此,由于中央贾瓦河电网其他地方的不平衡故障而导致的电压骤降将直接传递到卡利旺古工业中心的家用电器。已经提出了几种相对低成本的解决方案来减轻这种情况。提出的解决方案是修改直接向该区域供电的变电站中的变压器绕组连接和接地系统。仿真结果表明了所提出解决方案的有效性。