Analyte capture in microfluidic heterogeneous immunoassays

机译:微流体异质免疫分析中的分析物捕获

获取原文
获取外文期刊封面目录资料

摘要

Despite the prevalence of microfluidic-based heterogeneous immunoassays, there is incomplete understanding of analyte capture parameters. This study presents computational results and corresponding experimental binding assays of analyte capture. Our results identify: 1) a ¿reagent-limited¿ regime, under constraints of finite sample volume and assay time; 2) a critical flow rate; 3) an increase in signal by using a short concentrated plug rather than a long dilute plug; 4) a requirement to eventually reach a reaction-limited operating regime to maximize the capture of analytes.
机译:尽管基于微流体的异质免疫测定很普遍,但对分析物捕获参数的理解还不完全。这项研究提出了分析物捕获的计算结果和相应的实验结合测定。我们的结果确定:1)在有限的样品量和测定时间的约束下,有一个ƒ‐,,¿ 2)临界流速; 3)通过使用短的集中插头而不是长的稀释插头来增加信号; 4)要求最终达到反应受限的操作方案,以最大程度地捕获分析物。