This paper presents a comprehensive discussion about enhanced performance of integrated high voltage charge pumps by means of the introduction of proposed advanced clock schemes with dead time techniques. The theoretical analysis is supported by both simulation and experimental results. This paper is therefore intended to provide charge pump circuit designers an extensive understanding of advantages of dead time techniques and the corresponding possibilities to improve the circuit performance.
机译:本文通过引入具有空载时间技术的先进时钟方案,对集成高压电荷泵的增强性能进行了全面的讨论。理论分析得到仿真和实验结果的支持。因此,本文旨在为电荷泵电路设计人员提供对死区时间技术的优势以及提高电路性能的相应可能性的广泛理解。