首页> 外文会议>IABSE symposium on tomorrow's megastructures >Seismic analysis of the San Sebastian Basilica (Philippines)
【24h】

Seismic analysis of the San Sebastian Basilica (Philippines)

机译:圣塞瓦斯蒂安大教堂(菲律宾)的地震分析

获取原文
获取外文期刊封面目录资料

摘要

This paper presents the evaluation of the seismic performance of the San Sebastian Basilica, which included dynamic identification tests, preparation of numerical models and pushover analyses. The San Sebastian Basilica, located in Manila and inaugurated in 1891, consists of a fully prefabricated steel structure that has maintained its original design, interior finishes and materials. The dynamic identification tests were carried out using ambient vibration, which allowed to estimate six modes (2.53 Hz to 5.81 Hz). The FEM models employ an evolutionary process to assess the importance of the addition of various elements on the dynamic properties of the basilica. The seismic analysis allowed the conclusion that the transverse direction of the Basilica presents the lowest capacity, namely 2.5 g and 3.6 g for the uniform and first mode loading pattern, respectively. However, further works should be conducted to conclude on the safety of the basilica for seismic action.
机译:本文介绍了圣塞巴斯蒂安大教堂的抗震性能评估,包括动态识别测试,数值模型的准备和推覆分析。位于马尼拉的圣塞瓦斯蒂安大教堂始建于1891年,由完全预制的钢结构组成,保留了其原始设计,室内装饰和材料。动态识别测试是使用环境振动进行的,可以估计出六个模式(2.53 Hz至5.81 Hz)。有限元模型采用了进化过程来评估添加各种元素对大教堂动态特性的重要性。地震分析得出的结论是,大教堂的横向方向呈现出最低的容量,即均匀模式和第一模式加载模式分别为2.5 g和3.6 g。但是,应该做进一步的工作来总结大教堂地震作用的安全性。