The performance of earthing systems atrntransmission line tower bases has become important inrnrecent years. The main issue concerns electrical safetyrnaround the base of the tower under power frequencyrnfault or lightning conditions. Such events present arnsafety hazard, described in terms of step and touchrnpotentials. Previous published work has focussedrnmainly on the performance of substation earthingrnsystems. In this work, the performance of an operationalrn275kV tower base has been monitored over a period ofrntwo years. A series of a.c. and d.c. fall-of-potentialrnmeasurements have been carried out to determine thernearth impedance of the structure. Touch voltages havernalso been measured in the vicinity of the tower base. Inrnaddition, the soil resistivity in the locality was measuredrnperiodically and the effect of seasonal changes werernrecorded. This allowed the variation in tower earthrnimpedance to be correlated with measured soilrnresistivity changes.
机译:输电线路铁塔基地的接地系统的性能已成为重要的最近几年。主要问题涉及在工频故障或雷电条件下铁塔底部周围的电气安全性。此类事件存在安全隐患,以步进和接触电位描述。先前发表的工作主要集中在变电站接地系统的性能上。在这项工作中,在长达两年的时间里对275kV塔式基地的运行性能进行了监控。一系列交流和d.c.已经进行了电位下降测量来确定结构的接地阻抗。还已经在塔架基座附近测量了接触电压。此外,还定期测量了当地的土壤电阻率,并记录了季节变化的影响。这使得塔接地阻抗的变化与测得的土壤电阻率变化相关。