Vertical earth rods are very importantrncomponents of lightning protection. They are used inrntransmission and distribution systems.rnA detailed parametric analysis is carried out torncharacterise the performance of an earth rod usingrnearth design software (HIFREQ module [1]) and twornequivalent circuits (Lumped and Distributed circuits).rnSeveral works has been don on the characteristics ofrnthe earth rod under transients [2-7]. The BritishrnStandard is recommended 10 ohm earth electrodernresistance [8].rnThis paper presents the performance of the earthrnelectrode over a high range of frequencies from 50 Hzrnto 50 MHz. The parameters that are varied arernfrequency, rod length, rod radius, soil resistivity andrnsoil permittivity.rnAlso the models are studded under number of impulsernsurges.rnThe earth rod used in the simulation, of 5m length andrn7mm radius.
机译:垂直接地棒是防雷非常重要的组成部分。它们被用于输电和配电系统。rn使用接地设计软件(HIFREQ模块[1])和两个等效电路(集总电路和分布式电路)对接地棒的性能进行了详细的参数分析。在瞬变条件下接地棒的安装[2-7]。推荐使用BritishrnStandard 10欧姆接地电极电阻[8]。本文介绍了接地电极在50 Hz至50 MHz高频范围内的性能。随频率,杆长度,杆半径,土壤电阻率和土壤介电常数的变化而变化的参数。rn还对模型进行了冲动数量的模拟。模拟中使用的接地棒长度为5m,半径为7mm。