This study presents a numerical assessment of consolidation under vacuum preloading with arnsystem of vertical drains and membrane, considering the non-linear properties of the soil Thisrnmembrane system, already widely used in Australia, is where an airtight membrane is placed overrnthe drainage layer to allow a vacuum to be distributed within the sand platform, along the surfacernof the soil, and down the vertical drains. To date, there have only been a few fundamentalrninvestigations and field studies that have tried to assess the way in which the vacuum canrnpropagate in soft clay, both laterally and vertically. In this model, both vertical and horizontalrndrainage was considered to reflect more realistic in-situ conditions. Moreover, the change ofrncompressibility and permeability during consolidation was taken into consideration, including arnpossible loss of vacuum along the length of the drain. This model was initially verified for a singlerndrain using large scale laboratory testing, and subsequently applied to a fully instrumented casernstudy, namely the Ballina Bypass (along the Pacific Highway, NSW). The numerical solutionsrncapturing the lateral distribution of the vacuum provided accurate predictions of the pore waterrnpressure and associated settlement.
机译:考虑到土壤Thisrn-membrane系统的非线性特性(已在澳大利亚广泛使用),该研究提出了在真空预压下使用垂直排水沟和膜的神经系统进行固结的数值评估,该系统在排水层上放置了一层气密的膜,以允许真空将沿着土壤表面沿着垂直排水沟分布在沙平台内。迄今为止,只有很少的基础研究和现场研究试图评估真空黏土在横向和垂直方向上在软粘土中的传播方式。在该模型中,垂直排水和水平排水都被认为反映了更现实的现场条件。此外,考虑了固结过程中可压缩性和渗透性的变化,包括沿排水管长度可能会损失真空。最初使用大型实验室测试验证了该模型的单一排水沟,然后将其应用于功能齐全的案例研究,即Ballina Bypass(沿新南威尔士州太平洋公路沿线)。捕捉真空横向分布的数值解提供了孔隙水压力和相关沉降的准确预测。

著录项

  • 来源
  • 会议地点 Melbourne(AU)
  • 作者单位

    Centre for Geomechanics Railway Engineering, ARC Centre of Excellence for Geotechnical Science and Engineering, University of Wollongong, Wollongong City, NSW 2522, Australia, PH (+61) 2 4221 3385, FAX (+61) 2 4221 3238, email: xgeng@uow.edu.au;

    Centre for Geomechanics and Railway Engineering, Program Leader, ARC Centre of Excellence for Geotechnical Science and Engineering, University of Wollongong, Wollongong City, NSW 2522, Australia, PH (+61) 2 4221 3046, FAX (+61) 2 4221 3238, email: indra@uow.edu.au;

    Centre for Geomechanics Railway Engineering, ARC Centre of Excellence for Geotechnical Science and Engineering, University of Wollongong, Wollongong City, NSW 2522, Australia, PH (+61) 2 4221 5852, FAX (+61) 2 4221 3238, email: cholacha@uow.edu.au;

    Coffey Geotechnics, NSW 2066, Australia email: Richard_Kelly@coffey.com.au;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Membrane system; vertical drain; non-linear analysis; Ballina By-pass; soft clay;