摘要

The combustion efficiency of coal-fired power stations can be improved if three critical parameters, relating to the flow of pulverised fuel, are measured and (ideally) controlled. These are the solids velocity, the solids distribution between pipes or 'split' and the particle size. Three prototype devices manufactured by ABB Instrumentation which measure these parameters were fitted to 14" (350mm) diameter pneumatic conveyors leading to the furnace burners at the Scottish Power plant, Methil Power Station in Scotland. This paper describes the systems used and presents some of the test results. The instrumentation will be commercially available in 1998.
机译:如果测量和(理想地)控制与粉状燃料流量有关的三个关键参数,则可以提高燃煤电站的燃烧效率。这些是固体速度,管道之间或“分裂”之间的固体分布以及粒径。将三个由ABB Instrumentation生产的可测量这些参数的原型设备安装到14英寸(350毫米)直径的气动输送机上,该输送机通向苏格兰Methil电站的苏格兰电厂的炉膛燃烧器。本文介绍了所使用的系统,并介绍了其中的一些系统。测试结果:该仪器将于1998年商用。