【24h】

Environmental and optical power testing of high attenuation fibers

机译:高衰减光纤的环境和光功率测试

获取原文
获取原文并翻译 | 示例

摘要

Cobalt-doped high attenuation fibers were tested in terms of temperature, humidity, and optical power. The maximum attenuation variation recorded was less than 3 % for temperatures between -40 to + 65℃ under uncontrolled humidity. When the humidity was controlled, the maximum attenuation variation was less than 3 % under the worst case: +85℃ and 85 % R.H. Optical power test were carried out at 1W and 1550 nm over 12 minutes without any recorded damage to the fibers.
机译:对钴掺杂的高衰减光纤进行了温度,湿度和光功率方面的测试。在不受控制的湿度下,-40至+ 65℃之间的温度记录的最大衰减变化小于3%。在控制湿度的情况下,最坏情况下的最大衰减变化小于3%:+ 85℃和85%R.H.在1W和1550 nm下进行了12分钟的光功率测试,未记录到光纤损坏。