首页> 外文会议>Environment Sensitive Cracking and Corrosion Damage(ESCCD 2004) >Investigation of Corrosion Mechanism of Condenser Tube in a Power Plant
【24h】

Investigation of Corrosion Mechanism of Condenser Tube in a Power Plant

机译:电厂凝汽管腐蚀机理的研究

获取原文
获取原文并翻译 | 示例

摘要

The composition and mechanical properties of the in-service condenser tube were analyzed, and the morphology of the inside surface and the cross-hatch marks were observed. Results exhibit that the composition and mechanical properties of the in-service tube were comparable to the original tube. The cross-hatch marks made an angle of 45 degree with the tube axis, and appeared mostly at the underside of the tube. After the corrosion product was removed, the bottom of the cross-hatch mark was studied which was characterized by corroded along some special crystal plane. Simulation tests of corrosion fatigue show that under a low applied cyclic stress, some corrosion stripes, similar to the cross-hatch marks, appear on the tube surface in a 3.5% NaCl solution. This result indicates that dislocation movement caused by a low cyclic stress induces the benzotriazole coating broken resulting in the corrosion along some special crystal plane.
机译:分析了在用冷凝器管的组成和力学性能,观察了其内表面的形态和交叉阴影线。结果表明,在用管的组成和力学性能与原始管相当。交叉影线标记与试管轴线成45度角,并且主要出现在试管的下侧。去除腐蚀产物后,研究了划格线的底部,该划痕的特征是沿某些特殊的晶面腐蚀。腐蚀疲劳的模拟测试表明,在较低的循环应力下,在3.5%NaCl溶液中,管表面上会出现一些类似于交叉影线的腐蚀条纹。该结果表明,由低循环应力引起的位错运动引起苯并三唑涂层破裂,导致沿某些特殊晶面的腐蚀。