The aim of this paper is the evaluation of the smoke flow rate through an opening, separating two spaces, when a fire is developed in one of the two, in order to verify possible control of, reducing oxygenation, fire grow by an air curtain recirculating indoor air. The study relates to a real urban underground railway station, with safe space to allow people to be evacuated, during a fire in the dock. The numerical approach is based on the package FDS (Fire Dynamics Simulator), developed by the NIST centre. The results show that an air curtain can reduce fire oxygenation, but is unable to extinguish fire for oxygen deficiency.
机译:本文的目的是评估在两个空间之一中发生火灾时,通过分隔两个空间的开口的烟气流量,以验证可能的控制,减少氧合作用,通过气幕再循环产生的火灾室内空气。该研究涉及一个真正的城市地下火车站,该码头具有安全的空间,可在码头发生火灾时疏散人员。数值方法基于NIST中心开发的软件包FDS(火灾动力学模拟器)。结果表明,气幕可以减少火的氧合,但不能消除因缺氧而引起的火。