【24h】

Simulation of Auxiliary Power System Operating State for 600 Mw Air-Cooling Unit

机译:600 Mw空冷机组辅助电源系统运行状态的仿真

获取原文
获取原文并翻译 | 示例

摘要

At present, 600MW high-capacity unit is the main of auxiliary power system, there are many loads and complex wirings, as the auxiliary power system operating state plays an important role, so it is very important to simulate the operation of system and analyze the reliability of all buses and short-circuit current. The latest engineer-designing software (ETAP) of auxiliary power system is used in this paper, the model of this system is established to simulate the operating state, then the reliability, power flow, short-circuit current, motor starting checkout, power consumption rate are calculated, Operating state is analyzed, and all the calculated data will provide a basic reference for the future designing.
机译:目前,600MW大容量机组是辅助电源系统的主体,负载多,接线复杂,由于辅助电源系统的运行状态起着重要作用,因此对系统的运行进行仿真和分析非常重要。所有母线的可靠性和短路电流。本文使用了最新的辅助电源系统工程师设计软件(ETAP),建立了该系统的模型来模拟运行状态,然后对可靠性,功率流,短路电流,电动机启动检查,功耗进行仿真。计算出速率,分析工作状态,所有计算出的数据将为将来的设计提供基本参考。