This paper described two accidents of 220 kV GIS Equipment in the Damao substation. According to the physics and chemistry testing results and the accidents phenomenon, the paper pointed out: The main reason for accident of 4.23 GIS equipment is that it was assembled in the adverse circumstance where is full of chemical fiber floater and flying dust, then the impurities flew into the bus bar; The main reason for accident of 8.6 GIS equipment is that workers neglected the drying procedure of a molecular sieve, then the moisture and impurities dropped into the CT air chamber. This paper made some suggestions about management and technology of the GIS equipment.
机译:本文介绍了大帽变电所发生的两次220 kV GIS设备事故。根据理化测试结果和事故现象,指出:4.23 GIS设备发生事故的主要原因是组装在充满化学纤维浮子,飞扬粉尘,杂质的恶劣环境下。飞进巴士吧; 8.6 GIS设备发生事故的主要原因是工人忽视了分子筛的干燥程序,然后水分和杂质掉入了CT气室。本文对GIS设备的管理和技术提出了一些建议。