Comparative spectrum analysis of vascular wall of brachiocephalic arteries in norm and atherosclerosis

机译:规范性和动脉粥样硬化性腕脑动脉血管壁的比较光谱分析

获取原文
获取原文并翻译 | 示例

摘要

Abstract: Since the late 1960s atherosclerotic plaque (AP) laser ablation techniques have been developed. Clinical data obtained with CW laser vaporization AP shows significant impairment of tissues close to plaque with following severe complications in postoperation period. The use of excimer pulsed laser decreases the harmful effects of laser radiation. However, data on spectrum of energy absorption by molecular AP structures are required for selective photodynamic action of UV laser emission. The aim of the present study is to estimate IR and UV absorption and fluorescence spectrum of intact and atherosclerosis-induced changes in aorta and brachiocephalic trunk. Autopsied vessel specimens with artery decease were analyzed. Absorption spectrum of frozen vessel slices (15 $mu@m) and oil emulsion was recorded. Characteristic absorption bands in 3000 cm$+$MIN@1$/ were noted as for AP as for intact tissue. In 1700 cm$+$MIN@1$/ AP IR spectrum has an absorption band which is not seen in normal tissue spectrum. Reflection spectrum of intact vessel wall surface and AP at range 45000 to 11000 cm$+$MIN@1$/ was recorded as well. In 32000 cm$+$MIN@1$/ reflection was 66% and 43% for AP and intact tissue, respectively. At range 17000 to 13000 cm$+MIN@1$/ curve position is changed: reflection for AP-66%, for intact wall-93%. Thus, reflection, absorption and fluorescence spectrum of intact and atherosclerotic vessels vary significantly. It provides us with a basis for intravessel examination and selection of laser parameters for harmless endovascular surgery. !3
机译:摘要:自1960年代后期以来,已经开发出了动脉粥样硬化斑块(AP)激光消融技术。 CW激光汽化AP获得的临床数据显示,术后严重并发症严重,斑块附近的组织明显受损。准分子脉冲激光的使用减少了激光辐射的有害影响。但是,分子AP结构吸收能量的光谱数据对于UV激光发射的选择性光动力作用是必需的。本研究的目的是评估完整的和动脉粥样硬化引起的主动脉和头臂干的变化的红外和紫外吸收以及荧光光谱。分析具有动脉疾病的尸检血管标本。记录冷冻的血管切片(15μm)和油乳剂的吸收光谱。对于AP和完整组织而言,注意到3000 cm ++ MIN @ 1 $ /的特征吸收带。在1700 cm ++ MIN @ 1 $ / AP中,IR光谱具有正常组织光谱中看不到的吸收带。还记录了完整血管壁表面和AP在45000至11000 cm $ + $ MIN @ 1 $ /范围内的反射光谱。在32000 cm ++ MIN @ 1 $ /中,AP和完整组织的反射分别为66%和43%。在17000到13000 cm $ + MIN @ 1 $ /范围内,曲线位置发生变化:AP反射率为66%,完整壁反射率为93%。因此,完整和动脉粥样硬化血管的反射,吸收和荧光光谱有显着变化。它为我们进行血管内检查和为无害血管内手术选择激光参数提供了基础。 !3

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号