首页> 外文会议>Conference on Ultraviolet Ground-and Space-based Measurements, Models, and Effects III; Aug 4-6, 2003; San Diego, California, USA >The US EPA Brewer Spectrophotometer Network and the USDA UVB Monitoring and Research Program: Data comparison from co-located instruments
【24h】

The US EPA Brewer Spectrophotometer Network and the USDA UVB Monitoring and Research Program: Data comparison from co-located instruments

机译:美国EPA Brewer分光光度计网络和USDA UVB监测和研究计划:位于同一地点的仪器的数据比较

获取原文
获取原文并翻译 | 示例

摘要

Several ground based ultraviolet (UV) monitoring networks exist in the United States, each of which is unique in the instrumentation employed for measurements. Two of these UV networks are the US EPA's Brewer Spectrophotometer network and the USDA's UVB Monitoring network, with a combined instrument total of 52 sites throughout the mainland USA, US territories and some overseas locations. The Brewer records full sky spectra from 287-363nm with 0.5nm resolution whereas the USDA instrument is a broadband device that measures broadband erythemally weighted UV data over a number of bands in the UV. To date, limited comparisons of data collected from these networks have been analyzed for comparative and quality assurance (QA) purposes. The data used in this paper is taken from sites where instruments from each program are co-located, namely, BigBend National Park, Texas and Everglades National Park, Florida. In order to reduce the contribution of errors in the Brewer-based instruments, the raw data has been corrected for stray light rejection, the angular response of the full sky diffuser, the temperature dependence of the instruments and the temporal variation. This reduces the estimated errors of the absolute irradiance values of each Brewer spectral measurement to approximately +-5%. The estimated uncertainty of the USDA instruments is also +-5%. Uncertainty is comprised of ⅰ) standard lamp measurement errors, ⅱ) spectral response determination and ⅲ) the angular response of the diffuser. In this paper, we perform spectrally resolved comparisons between the Brewer UV irradiance measurements and the data collected by the broadband erythemal UV meters at co-located sites between 1997 through to 2002.
机译:美国存在几个基于地面的紫外线(UV)监视网络,每个网络在用于测量的仪器中都是唯一的。这些紫外线网络中的两个是美国EPA的Brewer分光光度计网络和USDA的UVB监测网络,在美国大陆,美国领土和一些海外地区共有52个站点。布鲁尔以0.5nm的分辨率记录了287-363nm的全天空光谱,而USDA仪器是一种宽带设备,可在多个UV波段上测量宽带红斑加权UV数据。迄今为止,出于比较和质量保证(QA)的目的,已经分析了从这些网络收集的数据的有限比较。本文中使用的数据来自每个程序的仪器并置的站点,即德克萨斯州的BigBend国家公园和佛罗里达的Everglades国家公园。为了减少基于Brewer的仪器中的误差,已对原始数据进行了校正,以抑制杂散光,全天散光器的角度响应,仪器的温度依赖性和时间变化。这将每个Brewer光谱测量的绝对辐照度值的估计误差降低到大约+ -5%。 USDA工具的估计不确定性也是+ -5%。不确定度包括ⅰ)标准灯的测量误差,ⅱ)光谱响应确定和and)扩散器的角度响应。在本文中,我们对1997年至2002年之间在同一地点的Brewer UV辐照度测量结果和宽带红斑UV测量仪收集的数据进行光谱解析比较。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号