Accuracy improvement method of the on-machine measurement system is proposed by a correction methodology of measurement data. A volumetric error model to synthesize transient thermal errors as well as geometric errors is developed. Geometric errors are determined by the off-line calibration procedure. Under the assumption that the on-machine measuring procedure is a pure cooling process, the transient thermal errors are modeled as exponential functions with different thermal time constants and gains. The thermal time constants characterize transient thermal responses of machine elements during the on-machine measurement. The gains are determined by measuring a 3D artifact twice when the on-machine measurement of a machined part is required. Total time taken for measuring the artifact is less than 5 minutes. Experiments are performed to verify the proposed method. The measuring accuracy of the on-machine inspection system has been improved from to 10 μm.
机译:通过对测量数据进行校正的方法,提出了一种提高机载测量系统精度的方法。建立了综合瞬态热误差和几何误差的体积误差模型。几何误差由离线校准程序确定。假设在机测量过程是纯冷却过程,则将瞬态热误差建模为具有不同热时间常数和增益的指数函数。热时间常数表征了在机上测量期间机器元件的瞬态热响应。当需要对机加工零件进行机上测量时,通过两次测量3D伪像来确定增益。测量伪影所需的总时间少于5分钟。进行实验以验证所提出的方法。机上检查系统的测量精度已从10μm提高到10μm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号