The Max-Planck-Institut fur extraterrestrische Physik (MPE) in Garching, Germany, operates the large X-ray beam line facility PANTER for testing astronomical systems. At PANTER a number of telescopes like EXOSAT, ROSAT, SAX, JET-X, ABRIXAS, XMM and SWIFT operating in the soft energy range (0.02 - 15 keV) have been successfully calibrated. In the present paper we report on an important upgrade recently implemented that enables the calibration of hard X-ray optics (from 15 up to 50 keV). Currently hard X-ray optics based on single and multilayer coating are being developed for several future X-ray missions. The hard X-ray calibrations at PANTER are carried out by a high energy source based on an electron gun and several anodes, able to cover the energy range from 4.5 up to 50 keV. It provides fluxes up to 10~4 counts/sec/cm~2 at the instrument chamber with a stability better than 1 %. As detector a pn-CCD camera operating between 0.2 and 50 keV and a collecting area of 36 cm~2 is used. Taking into account the high energy resolution of the CCD (145 eV at 6 keV), a very easy way to operate the facility in hard X-ray is in' energy-dispersive mode (i.e. with a broad-band beam). A double crystal monochromator is also available providing energies up to 20 keV. In this paper we present the first results obtained by using PANTER for hard X-ray characterizations, performed on prototype multilayer optics developed by the Osservatorio Astronomico di Brera (OAB), Milano, Italy, and the Harvard-Smithsonian Center for Astrophysics (CfA), Cambridge, MA, USA.
机译:位于德国加兴的马克斯-普朗克物理研究所(MPE)经营大型X射线束线设施PANTER,用于测试天文系统。在PANTER,已成功校准了在软能范围(0.02-15 keV)下运行的EXOSAT,ROSAT,SAX,JET-X,ABRIXAS,XMM和SWIFT等望远镜。在本文中,我们报告了最近实施的一项重要升级,该升级能够实现硬X射线光学器件的校准(从15 keV到50 keV)。目前,正在开发基于单层和多层涂层的硬X射线光学器件,以用于未来的多个X射线任务。 PANTER的硬X射线校准是通过基于电子枪和几个阳极的高能量源进行的,这些阳极能够覆盖4.5至50 keV的能量范围。它在仪器室提供的通量高达10〜4个计数/秒/ cm〜2,稳定性优于1%。作为探测器,使用工作在0.2至50 keV之间且收集面积为36 cm〜2的pn-CCD摄像机。考虑到CCD的高能量分辨率(6 keV时为145 eV),在硬X射线下操作设备的一种非常简单的方法是采用能量分散模式(即使用宽带束)。还可以使用双晶体单色仪,提供高达20 keV的能量。在本文中,我们介绍了使用PANTER进行硬X射线表征的第一个结果,该结果是由意大利米兰的Osservatorio Astronomico di Brera(OAB)和哈佛-史密森尼天文学中心(CfA)开发的原型多层光学器件执行的,美国马萨诸塞州剑桥市。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号