Effects of Radiation Damage on Astrometric CCDs: Comparison of STA700 and e2v Model 43 Detectors

机译:辐射损伤对星象CCD的影响:STA700和e2v 43型探测器的比较

获取原文
获取原文并翻译 | 示例

摘要

We report on the measurement results for two candidate astrometric CCD designs, the STA700 and the e2v CCD43. Both of these CCDs have been considered as design baseline CCDs for use in a high-precision astrometric instrument in space, similar to the one proposed for the FAME, DIVA, or AMEX missions. We have exposed one sample CCD of each design to a fluence of 5 x 10~9 p~+ cm~(-2) (@ 63.3 MeV), then measured the relevant readout noise, dark current, charge injection noise, and CTI performance. We compare the two CCDs and assess how well each mitigates radiation damage.
机译:我们报告了STA700和e2v CCD43这两种候选天文CCD设计的测量结果。这两种CCD都被认为是用于太空中高精度天文仪器的设计基准CCD,类似于为FAME,DIVA或AMEX任务提出的一种。我们已经将每种设计的一个CCD样本暴露于5 x 10〜9 p〜+ cm〜(-2)(@ 63.3 MeV)的通量下,然后测量了相关的读出噪声,暗电流,电荷注入噪声和CTI性能。我们比较了这两个CCD,并评估了每个CCD减轻辐射损伤的程度。