The performance evaluation model (MRCeye model) of CCD low light level imaging system is deduced on the basis of human eye models and experimental data. It is involved signal to noise in time frequency and modulation transfer function in spatial frequency. It is showed by calculation that the minimum value of MRC is obtained when spatial frequency equals to f_0 c / mrad, MRC increase with the decrease of spatial frequency when spatial frequency f is less than f_0 c / mrad, MRC increase with the increase of spatial frequency when spatial frequency f is larger than f_0 c / mrad, namely, The MRC has band-pass characteristic that is according to the characteristic of human eye.
机译:根据人眼模型和实验数据推导了CCD微光成像系统的性能评估模型(MRCeye模型)。它涉及时间频率中的信噪比和空间频率中的调制传递函数。计算表明,当空间频率等于f_0 c / mrad时,MRC取最小值,当空间频率f小于f_0 c / mrad时,MRC随空间频率的减小而增大,MRC随空间的增大而增大当空间频率f大于f_0 c / mrad时的频率,即MRC具有与人眼特性相对应的带通特性。