This work evaluates the potential of low-light level CCD (L3CCD, E2V Technologies Ltd) technology in mammographic X-ray diffraction imaging. The L3CCD camera applies gain before readout, thereby amplifying the signal without increasing read noise. This allows very small signals to be seen. A 1 cm~2 Gd_2O_2S:Eu coated L3CCD camera operated at -5℃ was used. The diffraction profiles of healthy and diseased breast tissue differ significantly. These differences are being exploited to create a higher tissue contrast than seen in conventional transmission mammography. Preliminary experiments at the Elettra synchrotron radiation source in Trieste have investigated the degree of image contrast achievable in breast tissue diffraction images. A human breast tissue phantom was scanned at various momentum transfer values to produce diffraction images using L3CCD camera. Results demonstrate that a significant contrast enhancement is achievable.
机译:这项工作评估了微光CCD(L3CCD,E2V Technologies Ltd)技术在乳腺X射线衍射成像中的潜力。 L3CCD相机在读出之前应用增益,从而在不增加读取噪声的情况下放大信号。这样可以看到很小的信号。使用在-5℃下操作的1 cm〜2 Gd_2O_2S:Eu涂层的L3CCD相机。健康和患病的乳腺组织的衍射曲线差异很大。这些差异被用来产生比常规透射乳腺X线摄影术更高的组织对比度。在的里雅斯特的Elettra同步加速器辐射源进行的初步实验研究了在乳腺组织衍射图像中可获得的图像对比度。使用L3CCD相机以各种动量传递值扫描人的乳房组织体模,以产生衍射图像。结果表明,可以实现显着的对比度增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号