Symmetrical push-pull low circle fatigue tests have been performed on high-strain X80 line pipe material.Micro-analysis has been performed for deformation mechanism as well.Results show that X80 high-strain line pipe material exhibited a higher ductility and long low-circle fatigue life.Cyclic softening is observed at low strain amplitude of 0.4% and 0.6%,however,cyclic softening occurred after slight cyclic hardening at high strain amplitude of 1.0%,1.2% and 1.4%.Generally,Cyclic response curves show that the cyclic softening occurred at all strains amplitude (0.4%~1.4%).Fractography analysis suggests that transgranular fracture with well-developed fatigue striations and obvious second crack is the predominant failure mode.The amount of second cracks is much fewer deformed in high-strain X80 line pipe material than that in conventional X80 line pipe material.TEM examination reveals that the primary deformation mode of two kinds of material was dislocation slipping.Abundant dislocation glide bands and dislocation cells are formed at grain boundary as strain amplitude increased.Deformation in ferrite has been suppressed and formation of dislocation cell inside the ferrite has been postponed due to large content of M/A constituent.
机译:对高应变X80管线管材料进行了对称的推拉式低圆疲劳试验,并对变形机理进行了微分析,结果表明,X80高应变管线管材料具有较高的延展性和较低的长时延。在0.4%和0.6%的低应变振幅下观察到循环软化,但是,在1.0%,1.2%和1.4%的高应变振幅下,轻微的循环硬化后发生了循环软化。断裂应变在0.4%〜1.4%的所有振幅下都发生了周期性的软化。断口分析表明,疲劳发展良好,二次裂纹明显的跨晶断裂是主要的破坏方式,在高应变下二次裂纹的数量较少。 X80线管材料比传统的X80线管材料.TEM检查显示,两种材料的主要变形模式是位错滑移。随着应变幅度的增加,在晶界形成了滑移带和位错单元。由于M / A成分含量较高,铁素体的形变得到抑制,铁素体内部的位错单元的形成被推迟。

著录项

  • 来源
    《CMI conference Beijing》|2012年|783-793|共11页
  • 会议地点 Beijing(CN)
  • 作者单位

    Master, CNPC Tubular Goods Research Institute, No.32 Dianzier Road, Xi'an, China, 710065;

    Master, CNPC Tubular Goods Research Institute, No.32 Dianzier Road, Xi'an, China, 710065;

    Master, CNPC Tubular Goods Research Institute, No.32 Dianzier Road, Xi'an, China, 710065;

    Master, CNPC Tubular Goods Research Institute, No.32 Dianzier Road, Xi'an, China, 710065;

    Doctor, CNPC Tubular Goods Research Institute, No.32 Dianzier Road, Xi'an, China, 710065;

    Doctor, CNPC Tubular Goods Research Institute, No.32 Dianzier Road, Xi'an, China, 710065;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 U692.22;
  • 关键词

    High-strain line pipe; Low-circle fatigue; Strain amplitude; Dislocation; M/A;

    机译:高应变管线;低圆疲劳;应变幅度;位错; M / A;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号