首页> 外文会议>Chemical and Biological Sensing VII >Biological Agent Detection based on Principal Component Analysis
【24h】

Biological Agent Detection based on Principal Component Analysis

机译:基于主成分分析的生物制剂检测

获取原文
获取原文并翻译 | 示例

摘要

This paper presents an algorithm, based on principal component analysis for the detection of biological threats using General Dynamics Canada's 4WARN Sentry 3000 biodetection system. The proposed method employs a statistical method for estimating background biological activity so as to make the algorithm adaptive to varying background situations. The method attempts to characterize the pattern of change that occurs in the fluorescent particle counts distribution and uses the information to suppress false-alarms. The performance of the method was evaluated using a total of 68 tests including 51 releases of Bacillus Globigii (BG), six releases of BG in the presence of obscurants, six releases of obscurants only, and five releases of ovalbumin at the Ambient Breeze Tunnel Test facility, Battelle, OH. The peak one-minute average concentration of BG used in the tests ranged from 10-65 Agent Containing Particles per Liter of Air (ACPLA). The obscurants used in the tests included diesel smoke, white grenade smoke, and salt solution. The method successfully detected BG at a sensitivity of 10 ACPLA and resulted in an overall probability of detection of 94% for BG without generating any false-alarms for obscurants at a detection threshold of 0.6 on a scale of 0 to 1. Also, the method successfully detected BG in the presence of diesel smoke and salt water fumes. The system successfully responded to all the five ovalbumin releases with noticeable trends in algorithm output and alarmed for two releases at the selected detection threshold.
机译:本文提出了一种基于主成分分析的算法,该算法使用加拿大通用动力公司的4WARN Sentry 3000生物检测系统来检测生物威胁。所提出的方法采用统计方法来估计背景生物活性,从而使算法适应于变化的背景情况。该方法试图表征荧光颗粒计数分布中发生的变化模式,并使用该信息来抑制错误警报。在环境微风隧道试验中,总共进行了68次测试,包括51次释放的芽孢杆菌(BG),六次释放的BG,仅六次的释放的雾剂和5次的卵清蛋白,评估了该方法的性能。设施,俄亥俄州巴特尔。测试中使用的BG的一分钟峰值平均浓度范围为每升空气含10-65个含毒剂颗粒(ACPLA)。测试中使用的遮盖剂包括柴油烟雾,白榴弹烟雾和盐溶液。该方法以10 ACPLA的灵敏度成功检测到BG,导致检测到BG的总概率为94%,而在检测阈值为0到0的范围内,未生成任何遮盖剂错误警报。在存在柴油烟雾和盐水烟雾的情况下成功检测到BG。系统成功响应了所有五个卵清蛋白释放,算法输出具有明显趋势,并在选定的检测阈值处发出两个释放警报。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号