摘要

Natural Gas Pipeline Company of America (NGPL), a subsidiary of Kinder Morgan, Inc., has been monitoring their pipeline system for the presence and severity of stress corrosion cracking (SCC) for more than thirty years. With the identification of near neutral pH SCC (also called low pH SCC) on this system, over the past five years NGPL has implemented a comprehensive SCC integrity management plan (IMP). Through their SCC IMP, NGPL has been finding and eliminating near critical near neutral pH SCC and other defects from their system, while using data from the program to obtain a better understanding of the relationship of SCC to existing pipe and environmental conditions. NGPL transports commercial quality natural gas to the Chicago area through a multi-line system that originates in various North American supply regions. The system right-of-way encompasses most of the American mid-west and crosses many physiographic areas. The pipelines have varying grades, diameters, and wall thicknesses, and were constructed at different times. Overall there are approximately 10,000 miles (16,000 kilometers) of pipeline that fall within the current NGPL SCC IMP. The primary purpose of this paper is to relate some of our experience with SCC on our system and describe the some of the innovative technical aspects of the existing in-house SCC IMP. This paper outlines some historical examples of the NGPL methodology for detecting near neutral pH SCC in pipeline steels using two or more separate pipeline investigation techniques. The basic steps of SCC direct assessment (DA) are described, as well as the process of integrating the predictive SCC model with in-line inspection (ILI) low level analysis signatures to determine the extent and severity of near neutral pH SCC on the NGPL pipeline system.
机译:Kinder Morgan,Inc.的子公司美国天然气管道公司(NGPL)对其管道系统的应力腐蚀开裂(SCC)的存在和严重性进行了三十多年的监控。在此系统上识别出接近中性的pH SCC(也称为低pH SCC)后,NGPL实施了全面的SCC完整性管理计划(IMP)。 NGPL通过他们的SCC IMP,发现并消除了系统中接近关键的接近中性pH的SCC和其他缺陷,同时使用程序中的数据来更好地了解SCC与现有管道和环境条件之间的关系。 NGPL通过多管道系统将商业质量的天然气运输到芝加哥地区,该系统起源于北美各个供应地区。该系统的通行权涵盖了美国中西部的大部分地区,并跨越了许多自然地理区域。管道具有不同的等级,直径和壁厚,并且在不同的时间建造。总体上,当前的NGPL SCC IMP范围内大约有10,000英里(16,000公里)的管道。本文的主要目的是将我们在SCC上的一些经验与我们的系统联系起来,并描述现有内部SCC IMP的一些创新技术方面。本文概述了使用两种或多种单独的管道调查技术检测管道钢中性pH SCC接近的NGPL方法的一些历史示例。描述了SCC直接评估(DA)的基本步骤,以及将预测SCC模型与在线检查(ILI)低水平分析特征进行整合以确定NGPL上接近中性pH SCC的程度和严重性的过程管道系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号