This paper examines and characterizes the structural response of intimately fitted repairedrnsewers due to disturbance in the vicinity (e.g. vehicle loads). This soil-host pipe-linerrninteraction is investigated by full scale laboratory testing. The test geometry andrnmeasurement scheme are described. Mechanisms affecting local bending at host pipernfractures are identified. A comparison is made between response for the HDPE linerrnwithin a fractured non-reinforced concrete pipe, and that same HDPE liner buried alonernin soil. Under earth disturbance, the fractures in the host pipe expanded at the innerrnsurface at the crown and invert, and at the outer surface at the springlines. Thisrnexpansion of fractures caused contacts between the inner edges of the host pipe and thernliner at the crown and invert. The liner response was dominated by the local bending thatrnresulted.
机译:本文研究并表征了由于附近的干扰(例如车辆载荷)而紧密贴合的维修过的污水管的结构响应。通过全面的实验室测试来研究这种土壤-宿主管道-衬里相互作用。描述了测试几何和测量方案。确定了影响主管道破裂处局部弯曲的机制。在破裂的非钢筋混凝土管中对HDPE衬砌的响应与单独埋在土壤中的相同HDPE衬砌的响应之间进行了比较。在大地扰动下,主管中的裂缝在顶部的内表面处扩展并倒转,在弹簧线处的外表面处扩展。裂缝的这种膨胀导致主管的内边缘与顶冠处的内衬之间发生接触并倒转。班轮反应主要是由局部弯曲引起的。

著录项

  • 来源
  • 会议地点 Cleveland OH(US);Cleveland OH(US);Cleveland OH(US)
  • 作者

    T.C. Michael Law; Ian D. Moore;

  • 作者单位

    Geotechnical Research Centre, The University of Western Ontario,London ON, Canada N6A 5B9 mlaw@engga.uwo.ca;

    Infrastructure Engineering, Department ofCivil Engineering, Queen's University, Kingston ON, Canada K7L 3N6moore@civil.queensu.ca phone: (613) 533 3160 fax: (613) 533 2128;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 管道设备;管道运输;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号