首页> 外文会议>ASME Turbo Expo vol.6 pt.A; 20050606-09; Reno-Tahoe,NV(US) >THE EFFECT OF ULTRAPOLISH ON A TRANSONIC AXIAL ROTOR
【24h】

THE EFFECT OF ULTRAPOLISH ON A TRANSONIC AXIAL ROTOR

机译:超声波对跨轴转子的影响

获取原文
获取原文并翻译 | 示例

摘要

Back-to-back testing has been done using NASA fan rotor 67 in the Glenn Research Center W8 Axial Compressor Test Facility. The rotor was baseline tested with a normal industrial RMS surface finish of 0.5-0.6 μm (20-24 microinches) at 60, 80 and 100% of design speed. At design speed the tip relative Mach number was 1.38. The blades were then removed from the facility and ultrapolished to a surface finish of 0.125 μm (5 microinch) or less and retested. At 100% speed near the design point, the ultrapolished blades showed approximately 0.3 - 0.5% increase in adiabatic efficiency. The difference was greater near maximum flow. Due to increased relative measurement error at 60 and 80% speed, the performance difference between the normal and ultrapolished blades was indeterminate at these speeds.
机译:背对背测试已使用Glenn研究中心W8轴向压缩机测试设施中的NASA风扇转子67完成。在设计速度的60%,80%和100%时,对转子进行了0.5-0.6μm(20-24微英寸)的正常工业RMS表面粗糙度的基线测试。在设计速度下,尖端的相对马赫数为1.38。然后将刀片从设备中取出并超抛光至0.125μm(5微英寸)或更小的表面光洁度,然后重新测试。在接近设计点的100%速度下,超抛光刀片的绝热效率提高了约0.3-0.5%。最大流量附近的差异更大。由于在60%和80%的速度下相对测量误差增加,因此在这些速度下,普通和超抛光刀片之间的性能差异是不确定的。