Measurement of permittivity and dissipation factor without attached electrodes

机译:在不连接电极的情况下测量介电常数和耗散因数

获取原文
获取原文并翻译 | 示例

摘要

When the determination of permittivity is made using attached electrodes, it is necessary to know the dimensions of the specimen. The thickness measurement is especially difficult, particularly for relatively thin specimens. For example, when the specimen is 10 mils thick an error of 0.1 mil in the thickness determination will result in a 1 percent error in the calculated permittivity. The difficulties become increasingly greater as the thickness of the specimens decreases.
机译:使用连接的电极确定介电常数时,必须知道样品的尺寸。厚度测量特别困难,特别是对于相对薄的样品。例如,当样品厚度为10密耳时,厚度确定中的0.1密耳误差将导致计算出的介电常数误差为1%。随着样品厚度的减小,困难变得越来越大。