【24h】

NUMERICAL SIMULATIONS OF AIR FLOW IN A FULL SCALE CLEAN ROOM INCORPERATING FAN CURVES OF FAN FILTER UNITS

机译:大型洁净室中不透风的通风通道的数值模拟。

获取原文
获取原文并翻译 | 示例

摘要

This manuscript presents the air flow fields and pressure distributions of a full scale class 100 semiconductor clean room system using a computational fluid dynamics (CFD) model that incorporates flow resistances of various components in the air path. The fan-performance curves of fan filter unit (FFU), the pressure - velocity curves of the dry coil and the ULPA are included in the model. The pressure and velocity distributions of the present simulation are in reasonable agreement with the measurement in the real clean room system during operation. The numerical methodology of the present work is found to be a useful design tool of a FFU type clean room for the estimation of clean room pressure, velocity distribution and air exchange rate.
机译:该手稿采用计算流体力学(CFD)模型,该模型结合了空气路径中各个组件的流动阻力,给出了全尺寸100级半导体洁净室系统的空气流场和压力分布。该模型包括风扇过滤器单元(FFU)的风扇性能曲线,干燥盘管的压力-速度曲线以及ULPA。本模拟的压力和速度分布与实际洁净室系统在运行期间的测量值合理地吻合。发现当前工作的数值方法是FFU型洁净室的有用的设计工具,用于估计洁净室压力,速度分布和空气交换率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号