【24h】

VISUALIZATION OF FLOW REGIME TRANSITIONS IN TWO-PHASE FLOW UNDER HIGH VOLTAGE ELECTRIC FIELDS

机译:高压电场下两相流中流态转变的可视化

获取原文
获取原文并翻译 | 示例

摘要

The effects of applying DC high voltage electric fields on two-phase flow regime transitions for flowing refrigerant HFC-134a were visualized using a high speed camera . The viewing test section was made of 10 mm inner diameter quartz tube with a 3.18 mm diameter charged electrode placed along the center of the tube. The quartz tube was coated with an electrically grounded transparent conductive film of Tin Oxide. The experiments were performed for mass flux (55 kg/m~2s < G < 263 kg/m~2s), quality (20% < x < 80%) and applied voltage (0 kV < V < 8 kV). The flow regime transitions depend on the flow regime prior to applying the EHD. For stratified flow, EHD increases the interfacial instabilities and causes liquid extraction to the upper section of the tube. When the flow regime is initially annular flow, EHD increases the uniformity of the annular film by extracting liquid from the thicker liquid regions into the vapor core.
机译:使用高速摄像头可以看到在流动的制冷剂HFC-134a的两相流态转换中施加直流高压电场的效果。观察测试部分由内径为10 mm的石英管制成,其直径为3.18 mm的带电电极沿管的中心放置。石英管涂有一层接地的氧化锡透明导电膜。进行质量通量(55 kg / m〜2s