Single crystal of Pb(Mg~(1/3)Nb~(2/3))O_3-PbTiO_3 (PMN-PT), as one of the best pyroelectric materials, wasrnfirst discovered by Chinese scientist. In this paper, PMN-PT was selected as pyroelectric detectorrnmaterial. Firstly, an electrically calibrated pyroelectric detector with special structure was developed forrncalibration of radiation. The sensitive area of the detector is 10mm×10mm and the entrance aperturernis Φ8mm. The research about the coating film on the surface of the sensitive area was carried out.rnCarbon nanotubes (CNTs) were selected as the coating material. The responsivity of the detector isrnabout 18.3 V/W at 14 Hz. The detectors were used to establish an electrically calibrated system withrnuncertainty less than 4% at room temperature. The relative deviation of measurement is less than 3 %rnbetween 0.2 W/m~2 and 200 W/m~2, and the relative deviation is less than 5 % between 0.002 W/m~2 andrn0.02 W/m~2. Secondly, a 128×1 linear array was designed and fabricated. The responsivity of the linearrnarray is 3.5×10~4 V/W at 10 Hz, and the noise equivalent radiant power (NEP) is 0.4 nW. Thernpyroelectric array and CMOS read-out circuit were electrically bonded by ultrasonic bonding processrnto be uncooled focal plane array (FPA). The FPA was tested under different radiation intensity. Thesernresults lay a foundation for the development of high-performance uncooled pyroelectric FPA based onrnnovel ferroelectric single crystals.
机译:中国科学家首先发现了作为最佳热电材料之一的Pb(Mg〜(1/3)Nb〜(2/3))O_3-PbTiO_3单晶(PMN-PT)。本文选择PMN-PT作为热电探测器材料。首先,开发了一种具有特殊结构的电校准热释电探测器,用于辐射的校准。探测器的敏感区域为10mm×10mm,入口孔径为Φ8mm。对敏感区域表面的涂膜进行了研究。选择碳纳米管(CNTs)作为涂层材料。检测器的响应度在14 Hz时约为18.3 V / W。检测器用于建立电校准系统,其室温不确定度小于4%。测量的相对偏差在0.2 W / m〜2至200 W / m〜2之间小于3%,相对偏差在0.002 W / m〜2至0.02 W / m〜2之间小于5%。其次,设计并制作了一个128×1的线性阵列。线性阵列在10 Hz时的响应率为3.5×10〜4 V / W,噪声等效辐射功率(NEP)为0.4 nW。通过超声键合工艺将热释电阵列和CMOS读出电路电连接为非冷却焦平面阵列(FPA)。 FPA在不同的辐射强度下进行了测试。这些结果为开发基于新型铁电单晶的高性能非冷却热电FPA奠定了基础。

著录项

  • 来源
    《AMA conference 2013》|2013年|89-94|共6页
  • 会议地点 Nurnberg(DE)
  • 作者单位

    Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China,shaoxm@mail.sitp.ac.cn;

    Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China,Graduate School of the Chinese Academy of Science, Beijing 100049, China;

    Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    PMN-PT; pyroelectric detector; finite element model; coatings; and uncooled FPA;

    机译:PMN-PT;热电探测器;有限元模型;涂层;以及未冷却的FPA;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号