首页> 外文会议>AMA conference 2013 >Evaluation of Heater Temperature to Detect Gases in a Flowing Fluid
【24h】

Evaluation of Heater Temperature to Detect Gases in a Flowing Fluid

机译:评估加热器温度以检测流动流体中的气体

获取原文
获取原文并翻译 | 示例

摘要

In this contribution the behavior of a calorimetric flow sensor was investigated, at which only therntemperature of the heater is evaluated. A time-dependent excitation (f = 1 Hz) was applied to thernheating element with a constant power amplitude. The influence of different gases and flow velocitiesrnon the heater temperature were observed. Measurements and simulations were carried outrnin no-flow condition and in flowing fluids in order to obtain the restrictions regarding to a simultaneousrndetection of flow speed and gas type. A simultaneous measurement of flow velocity and gas type wasrnpossible, however certain conditions had to be respected, e.g. a high difference in thermal conductivityrnwhich is predetermined by the flow speed range.
机译:在这一贡献中,研究了量热流量传感器的性能,在该性能下仅评估了加热器的温度。随时间变化的激励(f = 1 Hz)以恒定的功率幅度施加到加热元件上。观察了不同气体和流速对加热器温度的影响。为了获得关于同时检测流速和气体类型的限制,在无流量条件和流动流体中进行了测量和模拟。不可能同时测量流速和气体类型,但是必须考虑某些条件,例如:由流速范围预先确定的高导热率差rn。