摘要

When the scene observed by an imaging Fourier-Transform Spectrometer is not stable in amplitude or in position during the time it takes to acquire to spectrum, spectro-radiometric artifacts are generated. These artifacts reduce the radiometric accuracy and may also damage the spectral line shape. The displacements of the scene in the field of view can be due to air turbulence, platform jitters or scene jitters. We describe an automated correction process based on the information provided by the second output port of a two-port imaging FTS. Corrected and uncorrected data will be compared.
机译:当通过成像傅里叶变换光谱仪观察到的场景在获取光谱所需的时间内振幅或位置不稳定时,就会产生光谱辐射伪影。这些伪影会降低辐射测量的准确性,并且还会损坏光谱线的形状。场景在视场中的位移可能是由于空气湍流,平台抖动或场景抖动造成的。我们描述了基于两端口成像FTS的第二个输出端口提供的信息的自动校正过程。已校正和未校正的数据将进行比较。