【24h】

PERFORMANCE CHARACTERISTICS OF A MICROTURBINE-DOUBLE EFFECT ABSORPTION CHILLER CHP SYSTEM

机译:微涡轮双效吸收式制冷机CHP系统的性能特点

获取原文
获取原文并翻译 | 示例

摘要

A combined heat and power (CHP) system consisting of four natural gas-fired microturbines and a double effect absorption chiller/heater has been developed and tested. The system is designed to operate in one of three modes: Power Only, Power and Cooling, and Power and Heating. Depending on the operating mode, the system is capable of generating 240 kW of electrical power, 387 kW of cooling capacity, and 264 kW of heating capacity. This paper will present test results of the system performance, including power output, cooling and heating capacity, system fuel utilization, and sound levels for conditions representative of commercial buildings located in the United States.
机译:已经开发和测试了由四个天然气微型涡轮机和双效吸收式冷却器/加热器组成的热电联产(CHP)系统。该系统设计为以以下三种模式之一运行:“仅电源”,“电源和冷却”以及“电源和加热”。根据运行模式,该系统能够产生240 kW的电力,387 kW的冷却能力和264 kW的加热能力。本文将介绍系统性能的测试结果,包括功率输出,制冷和制热能力,系统燃料利用率以及代表美国商业建筑物状况的声级。

著录项