Requirements for accurate lattice thermal expansion measurements using Bragg-Brentanorndiffraction geometry are briefly described and results are shown for SRM676 aluminum oxide atrntemperatures up to 1000oC. These data demonstrate that careful consideration of systematicrnsample displacement and temperature is necessary to obtain reliable results. A comparison ofrnresults with and without calibrations to remove the systematic errors shows that ignoring thernerrors produces unreliable and unreasonable results.
机译:简要介绍了使用Bragg-Brentanorn衍射几何学进行精确晶格热膨胀测量的要求,并显示了温度高达1000oC的SRM676氧化铝的结果。这些数据表明,必须仔细考虑系统的样品位移和温度以获得可靠的结果。比较带有和不带有校准以消除系统误差的结果,可以发现忽略这些误差会产生不可靠且不合理的结果。