首页> 外文会议>Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2011 2nd International Conference on >Intracavitary in vivo dosimetry based on multichannel fiber-coupled Radioluminescence and Optically Stimulated Luminescence of Al2O3:C
【24h】

Intracavitary in vivo dosimetry based on multichannel fiber-coupled Radioluminescence and Optically Stimulated Luminescence of Al2O3:C

机译:基于Al2O3:C的多通道纤维耦合放射发光和光激发发光的腔内体内剂量测定

获取原文
获取原文并翻译 | 示例

摘要

Fiber Optic Dosimetric Catheters (FODCs) composed of chains of alumina crystals are investigated by the CEA LIST within the French ANR-INTRADOSE Project in the purpose of intracavitary in vivo dosimetry (IVD) during Brachytherapy (BT) with iridium sources and Intensity-Modulated Radiation Therapy (IMRT) with linear accelerators. A dedicated process involving PMMA fibers, casted altogether forming hexagonal bundle, is demonstrated. Optically Stimulated Luminescence (OSL) signals are recorded on-line after irradiation and absorbed doses are compared to planned dose distribution. Real-time dose measurements may also be performed by recording the RadioLuminescence (RL), spontaneously emitted by the crystals during irradiation. In this case, a correction method is implemented to correct for stem effect influence (Cerenkov and scintillation generated within the fibers). For BT, the dual-fiber subtraction method is used (using a reference fiber) whereas the time discrimination method is used for IMRT. The experimental dose distribution leads to an underestimation of the source-sensor distance presumably due to energy dependence of the alumina crystal at low photon energy. At the time being, Monte-Carlo modeling of the FODC is performed with the aim to estimate this energy dependence and finally correct for it. Finally, metrological and preclinical validations are still running at Centre Léon Bérard (Lyon, France) in the purpose of checking the compliance of the FODC prototypes with treatment specifications and medical constraints.
机译:法国ANR-INTRADOSE项目中的CEA LIST研究了由氧化铝晶体链组成的光纤剂量导管(FODC),目的是在使用铱源和强度调制辐射进行近距离放射治疗(BT)时进行腔内体内剂量测定(IVD)。带有线性加速器的疗法(IMRT)。演示了涉及PMMA纤维的专用工艺,该工艺共铸造成六角形束。照射后在线记录光刺激发光(OSL)信号,并将吸收的剂量与计划的剂量分布进行比较。实时剂量测量也可以通过记录辐射过程中晶体自发发射的放射性发光(RL)来执行。在这种情况下,将采用一种校正方法来校正茎效应的影响(纤维内产生的塞伦科夫和闪烁)。对于BT,使用双光纤减法(使用参考光纤),而时间区分方法用于IMRT。实验剂量分布可能导致低估了源传感器的距离,这可能是由于氧化铝晶体在低光子能量下的能量依赖性所致。当时,进行FODC的蒙特卡洛建模是为了估计这种能量依赖性,并最终对其进行校正。最后,计量和临床前验证仍在Leon on Bearard(法国里昂)中心进行,目的是检查FODC原型是否符合治疗规范和医疗约束。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号