The Air Distribution Research in Motor Control Center of Metallurgical Enterprises

机译:冶金企业电机控制中心的配风研究

获取原文
获取原文并翻译 | 示例

摘要

The motor control center (MCC) room exist the following problems: needing cooling year round, air conditioning energy consumption is very large, the MCC room air conditioning equipment type selection and the design of air distribution is unreasonable, and hot and cold air mixing serious, etc. In this paper, combining with specific MCC room, to study the application effect of the MCC room air conditioning system by CFD simulation method. The temperature and velocity fields in MCC room are compared and analyzed, then obtaining a more comprehensive, intuitional distribution rule of air velocity and temperature in MCC room. Presenting the proof for designing the air distribution in MCC room. The results show that: In under-floor air supply condition, air conditioning air flow directly sent into the cabinet and indoor environments , no mixing of hot and cold air flow, heat can be bring out the outdoor air flow successfully; in the up-inlet and down-outlet air supply condition, exhausted hot air stream floating up from cabinet is mixed with down-sent cold air steam , not only do this cause mixing of hot and cold air, but also suppress the flow stream with each other, which is not conducive to the discharge of heat.
机译:电机控制中心(MCC)机房存在以下问题:全年需要制冷,空调能耗非常大,MCC机房空调设备的选型和布局设计不合理,冷热空气混合严重本文结合特定的MCC机房,通过CFD模拟方法研究了MCC机房空调系统的应用效果。比较并分析了MCC室中的温度和速度场,从而获得了更全面,直观的MCC室中温度和速度分布规律。提供设计MCC室中的空气分配的证明。结果表明:在地板供气条件下,空调气流直接送入机柜和室内环境,冷热气流不混合,热量可以成功带出室外气流;在上,下出风口供气状态下,从机柜上浮下来的热气流与下送的冷空气蒸汽混合,不仅造成冷热空气的混合,还抑制了空气的流动。彼此之间,不利于散热。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号