【24h】

Study of Heat-source-tower Heat Pump System Effciency

机译:热源塔式热泵系统效率研究

获取原文

摘要

This paper introduced the forms and characteristics of heat-source-tower heat pump airconditioning system,analyzed its principle and working process,established closed source heat pump equipment and studied on the influence of heat source heat pump performance under different outdoor air parameters,making antifreeze and water as the heat transfer medium.Studies have shown that the wet-bulb temperature is 3.6°C,relative humidity is 80%,and it need to be sprayed antifreeze for frost prevention and at this time the system efficiency has increased 5% to 11%,suggesting that heat source heat pump can increase its efficiency under frost prevention conditions,which would provide guidelines for designing heat-source heat pump system.
机译:介绍了热源塔式热泵空调系统的形式和特点,分析了其原理和工作过程,建立了闭源热泵设备,研究了热源热泵性能在不同室外空气参数下的影响,并进行了防冻。研究表明,湿球温度为3.6°C,相对湿度为80%,需要喷洒防冻剂以防霜冻,此时系统效率提高了5%。 11%,建议热源热泵在防霜条件下可以提高效率,这将为热源热泵系统的设计提供指导。