In this paper, control strategies of a 22 MW / 27 MVA machine test bench using pumpback topology are introduced. The current loop design at extremely low pulse ratios (e.g. 600 Hz carrier frequency / 80 Hz load frequency) is developed. The system stability and dynamic response are analyzed. The challenges for high-power machine control with a sine filter and a transformer connected between the voltage-source-inverter and the machine are listed and solutions are given. Afterwards, some specific test modes are introduced as well. Finally, the control strategy is validated with the motor test at the customer site.
机译:本文介绍了一种使用抽水式拓扑结构的22 MW / 27 MVA机器测试台的控制策略。开发了具有极低脉冲比率(例如600 Hz载波频率/ 80 Hz负载频率)的电流环路设计。分析了系统的稳定性和动态响应。列举了在正弦滤波器和电压源逆变器与机器之间连接一个变压器的大功率机器控制所面临的挑战,并给出了解决方案。此后,还介绍了一些特定的测试模式。最后,在客户现场通过电机测试验证了控制策略。