An on-line UPS system that eliminates the inrush current phenomenon while feeding multiple load transformers

机译:一种在线UPS系统,可在为多个负载变压器供电时消除浪涌电流现象

获取原文
获取原文并翻译 | 示例

摘要

Numerous industrial facilities involve the installation of load transformers with their respective loads. As loads are turned on and off, these transformers are energized and de-energized, respectively, which can cause serious disturbances to sensitive loads. An inrush current, which typically occurs when a transformer is energized, can easily be observed using on-line uninterruptible power supply (UPS) systems feeding such loads. This paper proposes an on-line UPS system that eliminates the inrush current phenomenon caused by the energizing of load transformers. The UPS inverter specifically utilizes a fast acting current control scheme that enables it to regulate current for the load during all energizing conditions of load transformer connected to the UPS system.
机译:许多工业设施都需要安装带有各自负载的负载变压器。在打开和关闭负载时,这些变压器会分别通电和断电,这可能会对敏感负载造成严重干扰。使用为此类负载供电的在线不间断电源(UPS)系统可以轻松地观察到浪涌电流,该浪涌电流通常在变压器通电时发生。本文提出了一种在线式UPS系统,该系统可消除由负载变压器通电引起的浪涌电流现象。 UPS逆变器专门利用一种快速动作的电流控制方案,使它能够在连接到UPS系统的负载变压器的所有通电条件下调节负载的电流。