首页> 外文会议>7th international symposium on test and measurement (ISTM/2007) >Determination of Eugenol Using Flow Injection Analysis with Potassium Permanganate Chemiluminescence Detection
【24h】

Determination of Eugenol Using Flow Injection Analysis with Potassium Permanganate Chemiluminescence Detection

机译:流动注射-高锰酸钾化学发光检测法测定丁香酚

获取原文

摘要

A novel flow injection chemiluminescence (FI-CL) method for the fast, simple and sensitive determination of eugenol has been investigated. This is the first report on the determination of eugenol using flow injection analysis (FIA) with acidic potassium permanganate CL. It is based upon the direct CL reaction of eugenol and potassium permanganate in formaldehyde and sulfuric acid medium. Under the optimum conditions, the linear range for the determination of eugenol was 0.02 to 35 μg/mL. The detection limits (S/N = 3) was 0.007 μg/mL. The proposed method has been successfully applied to the determination of the eugenol in pharmaceutical formulations.
机译:研究了一种新型的流动注射化学发光(FI-CL)方法,用于快速,简单和灵敏地测定丁香酚。这是有关使用酸性高锰酸钾CL流动注射分析(FIA)测定丁香酚的第一份报告。它基于丁香酚和高锰酸钾在甲醛和硫酸介质中的直接CL反应。在最佳条件下,丁香酚含量的线性范围为0.02至35μg/ mL。检出限(S / N = 3)为0.007μg/ mL。所提出的方法已经成功地应用于药物制剂中丁香酚的测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号