This paper presents experimental results on the gag straightening effects of steel beams failed by lateral-torsional buckling. Eight different welded I-sections were tested under a central concentrated load at a simply supported beam. In the first buckling tests loads were applied until unloading region of approximately 60% of the maximum moment for each beam. After the residual deformations were straightened by press working, the second buckling tests were carried out under the same loading conditions. The ultimate strength and the rotation capacity were compared with the two cases in order to investigate their recovery.
机译:本文给出了关于由横向扭转屈曲破坏的钢梁的隔直校直效果的实验结果。在中央集中载荷下,在简单支撑的梁上测试了八个不同的焊接I型截面。在第一个屈曲测试中,施加载荷直到每个梁的卸载力矩约为最大力矩的60%。在通过冲压加工矫正残余变形之后,在相同的载荷条件下进行第二次屈曲测试。比较这两种情况的极限强度和旋转能力,以研究其恢复情况。