首页> 外文会议>4th international symposium on instrumentation science and technology >Study on the Concentration Measurement of the Pollution Gases from Coal-Fired Power Station
【24h】

Study on the Concentration Measurement of the Pollution Gases from Coal-Fired Power Station

机译:燃煤电厂污染气体浓度测量研究

获取原文
获取原文并翻译 | 示例

摘要

CO2 is a main kind of pollution gases discharged from coal-fired power station. The relationship between gas concentration and pressure, temperature is deduced base on the law of Beer-Lambert and the theory of gas line-shape. The tunable diode laser spectral technology is used to analyze the changing regularity of the peak, half-peak width of the absorption curve with pressure and temperature.
机译:二氧化碳是燃煤电厂排放的主要污染气体之一。根据比尔-朗伯定律和气体线形理论推导了气体浓度与压力,温度之间的关系。可调二极管激光光谱技术用于分析吸收曲线的峰值,半峰宽度随压力和温度的变化规律。