In China, Beijing, Shanghai and Guangzhou (BSG) are the most developed city in Jingjintang, Yangtze River Delta and Pearl River Delta areas respectively, so these cities' power system security is very important. In the conditions of a great deal power imported from outside, the local systems should be able to receive and response correctly in emergency. But at current transient voltage instability threatens the power systems of load centers seriously. In this paper, some typical transient voltage incidents are analyzed, the possibility of voltage instability and corresponding measures in BSG systems are studied, and the future work is presented.
机译:在中国,北京,上海和广州(BSG)分别是京津塘,长三角和珠三角地区最发达的城市,因此这些城市的电力系统安全非常重要。在从外部输入大量电力的情况下,本地系统应能够在紧急情况下正确接收和响应。但是在当前瞬态电压的不稳定性严重威胁着负载中心的电力系统。本文分析了一些典型的瞬态电压事件,研究了BSG系统中电压不稳定的可能性和相应的措施,并提出了今后的工作。