Sporadic cases of corrosion in electrical connectors have been found when the prewired connector assemblies were removed from factory sealed bags. In all such cases the corroded parts were terminated to wire per MIL-W-22759/33, the insulation being Ethylene-TetraFluoroEthylene (ETFE).rnTesting and analysis using advanced techniques such as lon Chromatography, Scanning Electron Microscopy (SEM) and Fourier Transform Infra Red (FTIR) Analysis have been applied to examine the wire insulation, the contacts and their plating, the metal shells and plating and finally the packaging bags.rnAll of the evidence indicates that exposed platings have reacted with fluoride ions from hydrofluoric acid formed by unpolymerized fluorides present in the wire insulation.rnThese excess fluorides and other volatiles can be removed by subjecting the wire to elevated temperatures. This must be done prior to sealing the wired assemblies in bags or any vessel or chamber where the volatiles would be trapped and in proximity to metals.
机译:从工厂密封的包装袋中取出预接线的连接器组件时,会发现电连接器出现零星腐蚀的情况。在所有这些情况下,腐蚀的零件均按照MIL-W-22759 / 33端接至电线,绝缘材料为乙烯-四氟乙烯(ETFE)。使用高级技术(例如,色谱法,扫描电子显微镜(SEM)和傅里叶变换)进行测试和分析红外(FTIR)分析已用于检查电线绝缘,触点及其镀层,金属外壳和镀层以及最后的包装袋.rn所有证据表明,暴露的镀层已与由氢氟酸形成的氢氟酸中的氟离子发生反应。电线绝缘层中存在未聚合的氟化物。这些多余的氟化物和其他挥发物可以通过使电线经受高温来去除。必须在将有线组件密封在袋子或任何容器或易挥发的容器或腔室中并靠近金属的位置之前进行此操作。