Penguin Dualstream II Wet Gas Measurement

机译:企鹅Dualstream II湿气测量

获取原文
获取原文并翻译 | 示例

摘要

The Penguin cluster is a formation of five different reservoirs located in the UK sector of the North Sea. It is produced via a 65km subsea tie-back to the Brent Charlie platform; the world’s third longest tie-back. The cluster is made up of five different reservoirs, each with significantly different gas to oil ratios. The gas volume fraction (GVF) of the arriving fluids is in the region of 85 to 95% and thus was considered to be too high for accurate (+-5%) measurement of the gas and oil phases using a multiphase meter (MPM) and too low for a wet gas meter. Due to the length of the tie-back a Severe Slug Suppression Device (S~3) was installed on the platform topsides. The S~3 in effect acts as a partial separator and thus the opportunity was taken to use this device to partially separate the fluids and hence move the MPM in to a more favourable operating environment. Consequently a 14 inch Solartron ISA Dualstream II (DS II) wet gas meter was installed on the wet gas outlet of the S~3 and a Framo Vx multiphase meter on the gassy liquid outlet. The outlet of these meters is then recombined prior to being routed either to the production or test separator. Prior to the production separator the Penguin fluids are commingled with the Brent fluids. As Brent pays Petroleum Revenue Tax and Penguin does not, there is a requirement for the metering to achieve an accuracy of +-5% on gas and oil. rnFollowing start-up it was observed that the readings from the DS II wet gas meter were out with the manufacturers specifications of +-5% for gas and +-10% for liquids. The meter was operating at a pressure of 35bar and Lockhart-Martinelli (LM) values of up to 0.5. Based on the information available it was concluded that the correction algorithms required for the Penguin meter differed significantly from those obtained with the previous much smaller 6 inch research meters (and on which the Penguin meter correlations had been based). rnWith a nominal pipe size of 14 inches, Penguin was by far the largest DS II meter Solartron ISA had manufactured, and unfortunately, at the time of manufacture there was no test facility that was realistically capable of testing the meter on wet gas. rnHowever, with the commissioning of the enhanced Statoil K-Lab wet gas test facility, it was decided that the best method to ascertain the cause of the flow meter discrepancy was to manufacture a second identical meter and to test it across as much of the operating range of the Penguin meter as possible. rnThis paper discusses the performance of the DS II meter immediately after first oil, the changes and onshore testing required to meet the specification, and the actual offshore testing of the new algorithms.
机译:企鹅群由位于北海英国部分的五个不同的水库组成。它是通过一条65公里长的海底绑扎带连接到Brent Charlie平台生产的;世界上第三长的后援。该集群由五个不同的储层组成,每个储层的气油比明显不同。到达的流体的气体体积分数(GVF)在85%到95%的范围内,因此对于使用多相流量计(MPM)准确测量(+ -5%)气相和油相而言,认为太高了对于潮湿的煤气表来说太低了。由于系带的长度,在平台顶侧安装了一个严重的塞子抑制装置(S〜3)。 S〜3实际上充当了部分分离器,因此有机会利用该设备来部分分离流体,从而将MPM移至更有利的操作环境中。因此,在S〜3的湿气出口上安装了14英寸的Solartron ISA Dualstream II(DS II)湿气表,并在气态液体出口上安装了Framo Vx多相流量计。然后将这些仪表的出口重新组合,然后再路由到生产或测试分离器。在生产分离器之前,将企鹅油与布伦特油混合。由于布伦特支付石油收入税而企鹅没有支付,因此计量要求使天然气和石油的准确度达到+ -5%。 rn在启动之后,观察到DS II湿式燃气表的读数超出了制造商的规定,气体为+ -5%,液体为+ -10%。仪表在35bar的压力下运行,洛克哈特·马丁尼(LM)值最高为0.5。根据可获得的信息,得出的结论是,企鹅仪表所需的校正算法与以前的小得多的6英寸研究仪表(以及企鹅仪表相关性所基于的算法)所获得的算法明显不同。企鹅的公称管道尺寸为14英寸,是迄今为止Solartron ISA生产的最大的DS II仪表,不幸的是,在制造时,还没有测试设备能够实际对湿气进行测试。 rn但是,随着增强的Statoil K-Lab湿气测试设备的启用,决定确定流量计差异原因的最佳方法是制造第二台相同的仪表并在尽可能多的运行中进行测试。企鹅表的最大范围。 rn本文讨论了首次注油后DS II仪表的性能,满足规格要求的变更和在岸测试以及新算法的实际海上测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号