【24h】

Preliminary study of a water cooled PV system

机译:水冷式光伏系统的初步研究

获取原文
获取原文并翻译 | 示例

摘要

This work deals to improve the efficiency of the photovoltaic panel efficiency by water cooling. This cooling system uses 50 g/s of water flow rate which circulates in a closed circuit between an insulated tank and the back side of the photovoltaic panel. Considering the climatic parameters of a typical summer day in Ghardaïa (south of Algeria), this system ensures a maximum PV panel temperature of 34.9 °C at 1.30 pm. Furthermore, the electrical efficiency of the cooled PV panel increases from 13.22 to 14.51%, from 11.47 to 14.31% and from 13.11 to 14.56%, respectively, at 8 am, 1 pm and 6 pm, compared to the situation of uncooled PV panel, exposed at the same climatic conditions. Moreover, this cooling system offers a maximum improvement of 25% at midday. In addition, the temperature field on the PV panel is almost homogeneous except at the junction box of electrical wires, where the PV panel heats locally.
机译:这项工作旨在通过水冷来提高光伏面板的效率。该冷却系统使用50 g / s的水流量,该水流量在隔热箱和光伏面板背面之间的闭合回路中循环。考虑到Ghardaïa(阿尔及利亚南部)一个典型夏日的气候参数,该系统可确保在1.30 pm时最高PV面板温度为34.9°C。此外,与之相比,冷却的光伏面板的电效率分别在上午8点,下午1点和下午6点从13.22%提高到14.51%,从11.47%增加到14.31%,从13.11%增加到14.56%。在相同气候条件下暴露于未冷却的光伏面板的情况。此外,该冷却系统在中午时最多可提高25%。另外,PV面板上的温度场几乎是均匀的,除了电线的接线盒处,PV面板局部加热。