In this paper we present and apply a methodology to create broadband models of power transformers in the frequency range from 9 kHz to 10 MHz. A power transformer of about 300 MVA rated power used at the interface between high voltage stations and AC-power grid is characterized in various operation modes by small signal measurements of the S-parameters. The measurement procedure is shown to provide passive and repeatable measurement data. We find that within the frequency range of interest the operation setting of the transformer like valve voltage or auxiliary power have only a minor impact on the measurements. The measured data is then post-processed to a black-box model describing the transformer as passive linear multiport. This model is then used in EMC system simulations of radiated emissions of full high voltage substations that are connected to the AC-grid by power transformers.
机译:在本文中,我们介绍并应用一种方法来创建在9 kHz至10 MHz频率范围内的电力变压器宽带模型。在高压站和交流电网之间的接口处使用的额定功率约为300 MVA的电力变压器,通过对S参数的小信号测量,以各种工作模式进行表征。显示的测量程序可提供被动和可重复的测量数据。我们发现,在感兴趣的频率范围内,变压器的运行设置(例如阀电压或辅助功率)对测量的影响很小。然后,将测得的数据后处理为黑箱​​模型,将变压器描述为无源线性多端口。然后,该模型将用于通过电源变压器连接到交流电网的全高压变电站的电磁辐射的EMC系统仿真中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号