首页> 外文会议>2018 Simposio Brasileiro de Sistemas Eletricos >Impact of receding horizon length under MBPC applied to DFIG based wind turbine
【24h】

Impact of receding horizon length under MBPC applied to DFIG based wind turbine

机译:MBPC下后退地平线长度对基于DFIG的风力发电机的影响

获取原文
获取原文并翻译 | 示例

摘要

During the last years, there has been presented many predictive controllers applied to Doubly Fed Induction Generators (DFIGs) based wind turbines. Due to the importance of this approach, this paper pretends to analyze the sensitivity of prediction and control horizon to a Model-Based Predictive Control (MBPC) using a space-state prediction model with an interior point optimizer, limited by the rotor voltage module constraint. The current study includes step response analysis, noise propagation, operation under different mechanical speeds and computational cost of MBPC algorithm.
机译:在过去的几年中,已经提出了许多应用于基于双馈感应发电机(DFIG)的风力涡轮机的预测控制器。由于这种方法的重要性,本文假装使用带有内部点优化器的空间状态预测模型来分析预测和控制范围对基于模型的预测控制(MBPC)的敏感性,该模型受转子电压模块约束的限制。当前的研究包括阶跃响应分析,噪声传播,在不同机械速度下的运行以及MBPC算法的计算成本。