首页> 外文会议>2017 Petroleum and Chemical Industry Conference Europe >High integrity electrical power system offshore oil gas facility
【24h】

High integrity electrical power system offshore oil gas facility

机译:高完整性电力系统海上油气设施

获取原文
获取原文并翻译 | 示例

摘要

The electrical power generation and distribution system for one of the Platform (Platform `A') was designed different from earlier fixed drilling and production platforms in the North Sea. The main difference is that there is no dedicated emergency generator on board. Instead each of the three main generators has been upgraded to a standard normally associated with emergency sets. This provides higher reliability of the electrical supply system and enables essential consumers such as firewater pumps to be powered by electricity. The system known as the High Integrity Electrical Power System (HIEPS) was originally used at another platform in order to save diesel units for the combined Firewater/Seawater (FW/SW) pumps. The Platform `A' design went one step further. The design used combined FW/SW pumps (to eliminate two diesel driven FW pumps) and also eliminated two diesel driven emergency generators. This paper discusses details of objectives leading to this design 25 years back and analysis based on the operator experience whether those objectives were met or not.
机译:其中一个平台(平台“ A”)的发电和配电系统的设计与北海较早的固定钻井和生产平台不同。主要区别在于船上没有专用的应急发电机。取而代之的是,三个主要发电机中的每一个都已升级到通常与应急装置相关的标准。这提供了更高的供电系统可靠性,并使诸如消防泵之类的重要消费者能够通过电力来供电。该系统最初被称为高完整性电力系统(HIEPS),最初是在另一个平台上使用,目的是为组合的消防水/海水(FW / SW)泵节省柴油单元。平台“ A”的设计又向前迈进了一步。该设计使用了组合式FW / SW泵(以消除两个柴油驱动的FW泵),并且还消除了两个柴油驱动的应急发电机。本文讨论了25年前实现该设计的目标的详细信息,并根据操作员的经验对这些目标是否实现进行了分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号