Ultra high frequency (UHF) and high frequency (HF) current partial discharge (PD) detection technology can detect PD phenomenon caused by internal defects of transformers, gas-insulated switchgear (GIS) and cable terminals and avoid insulation failure of the electrical equipment. Meanwhile, the Medical CT Imaging Technology provides reliable precise and intuitive measures for detecting human internal disease. Based on several real cases, this article raises the method to detect PD signal, diagnose and locate defects under the successful application of UHF, HF and Medical CT Imaging Technology in detecting and positioning internal gap defects of 110kv cable terminals and GIS. It also calculates PD distortion caused by internal gap defects using the Finite Field Simulation. All simulation results, field testing consequences, and the assembling of equipment with defects verify this method of diagnosis and detection efficient and scientific.
机译:超高频(UHF)和高频(HF)电流局部放电(PD)检测技术可以检测由变压器,气体绝缘开关设备(GIS)和电缆端子的内部缺陷引起的PD现象,并避免电气设备的绝缘故障。同时,医学CT成像技术可提供可靠,精确,直观的措施来检测人的内部疾病。在实际案例的基础上,提出了在UHF,HF和医学CT成像技术在110kv电缆端子和GIS内部间隙缺陷的检测与定位中成功应用的检测PD信号,诊断和定位缺陷的方法。它还使用有限场仿真计算由内部间隙缺陷引起的局部放电失真。所有的仿真结果,现场测试的结果以及有缺陷的设备的组装都证明了这种诊断和检测方法的效率和科学性。